ACCESS 200 48/200
AU4624
Data sheet
THE ACCESS SERIES
The Access series of industrial High Frequency battery charger from Micropower provides you with powerful and energy efficient battery charging and wireless communication. The modern state of the art MOSFET power conversion circuit efficiently and accurately converts AC power to the proper DC power levels required to charge different kinds of industrial batteries. Every Access charger can be set to perform both conventional charging and various levels of opportunity charging. There are several different charging curves available, such as for ionic mixing and opportunity charging, preprogrammed into every Access charger.COMMUNICATION
The Access charger is equipped with a radio transceiver that allows the charger to communicate with other chargers, with the Access BMU and Access Gateway. Using the Access BMU and Access Gateway allows you to gather and organize battery and charging data to help you optimize your battery fleet.ACCESS CONTROL
The Access charger is easily programmed to perform a variety of functions the way you want them performed. It constantly monitors the condition of the battery and automatically compensates for variations in battery temperature, age of the battery, and the battery’s condition.BEST BATTERY CHOICE
The Access charger can help you to select the best battery available in the charging room. The selection is made in order to ensure that all batteries are equally used and helps to promote best and coldest battery which has been ready the longest time. You can set up several groups of different battery sizes (V/Ah). This feature is standard in all Access chargers and can be implemented without additional hardware or software.OTHER FEATURES
- Energy efficient MOSFET design.
- Possibility to add three charge block-out periods to avoid times of peak demand and optimize energy cost if time of day billing are in use.
- Monday morning refresh charging.
- Wireless maximum power. This feature makes it possible to limit total power consumption for a group of chargers.
- Automatically equalizing cycles to ensure maximum lifetime for the battery.
A22
659 X 256 X 459
Air Pump
An alternative to ionic mixing where air bubbles are used to mix the battery acid. The air pump is fully integrated in the battery charger.
CAN-bus
The CAN-bus communication makes the battery charger very versatile and adds the possible to communicate with other systems using CAN-bus.
I/O Card
I/O cards can be equipped with up to 5 individual relays and can be used to control various functions such as an external LED-indicator, stacking beacon for charger status and remote start.
Automatic water filling
All our industrial High Frequency battery chargers can be equipped with a solenoid valve which is connected to the batteries water filling system. The system will automatically refill water into the battery when needed.
Safe Disconnect
All our industrial High Frequency battery chargers will automatically start when the battery charger is connected to the battery. Likewise it will automatically stop when the charger is disconnected. This option eliminates the risk of sparks when disconnecting the battery charger.
Battery Monitoring Unit (BMU)
Works seamlessly with Micropower Access chargers
When paired with any Micropower Access charger, the BMU handles charger configuration directly. Temperature monitoring is a mandatory input to the charger for fast and opportunity charging. The BMU also indicates charging capacity and cycle life, providing the information needed for efficient, long-term battery usage.NFC technology for instant access
Through Near Field Communication, data collected by the BMU is accessible from any Android phone. Just download the BMU mobile app, select the battery, and the data is in your hand. Data can also be retrieved via the Access Service Tool on any PC, then downloaded and transformed into graphs for battery fleet planning.Improved features
- State of charge indicator: Use the battery until charging is actually necessary
- Real backup for time and date settings: Eliminates statistical log errors
- New nail connectors: Prevent acid intrusion
- Flexible current sensor options: Up to >300A
Available in multiple models
The BMU comes in various models to match any lead/acid battery fleet - flooded or dry, soldered or bolted connectors.
For technical specifications, click here to learn more.
Service Tool
The Service Tool allows you to wirelessly download the complete charging statistics from the last 2000 charging cycles with history, events and 7000 momentary measurements. With the Service Tool, you can also program most battery charger's from Micropower and BMU (Battery Monitoring Unit) parameters wirelessly from your PC. For more information please click here.
Product brochure
ACCESS - Product brochure
Business segmentDYNAMIC POWER LIMITATION
Product brochureFAST AND OPPORTUNITY CHARGING
Product BrochureAGV TRACTION BATTERIES
Product brochureStep file
ACCESS 200 - 3D model [STEP file]
A22 EnclosureCollection
ACCESS 30–260 - User manual 'online version'
Battery chargerDrawing
ACCESS 200 - Air filter kit 16-20 kW drawing
AssemblyACCESS 200 - Enclosure drawing
A22 Overview and dimensionsBattery charger - Floor stand drawing
Example of different chargers mounted on floor standContact us today
Are you interested in the transition towards sustainable energy solutions?
Do you want to know more about batteries, charging or power converters?
Our dedicated team of experts are ready to assist you.